Horaizon Orthopedic Implants Horaizon Orthopedic Implants

Custom Patient Specific Implant Maxillofacial Repair and Fixation System

Customization: Available
Customized: Customized
Certification: ISO, CE

Product Description

📋 Basic Specifications
Condition
New
Usage
Correct Deformities, Fracture Fixation
Using Site
Head
OEM
Accept
Application
Craniomaxillofacial Repair and Reconstruction
Material
Medical Grade Titanium / PEEK
Specification
25x30x12cm
Capacity
50,000 pieces/Year
🔍 Product Overview
PEEK Patient Specific Implant
💡

PEEK Patient Specific Implant (PSI) provides an improved solution for patients with cranio-maxillofacial defects. Our technology and craftsmanship produce a perfect match to the specific anatomical requirement in a custom implant.

PEEK can be designed and provided in single or multiple pieces with just-fit or over-lay concepts. Additionally, this patient-specific implant can be reliably fixated using cranial fixation systems.

✨ Key Features
🛡️ Excellent Biocompatibility

Non-cytotoxic, corrosion resistance, non-carcinogenic, non-conductive, and hydrolysis resistance. Capable to sustain repeated steam, ETO sterilization, and Gamma irradiation.

⚙️ Outstanding Bio-Mechanical Character

Exceeding tensile strength to the native bone and provides better protection to the cerebrum. Comparable mechanical strength to artificial bone to distract stress effectively.

📸 Better Imaging Compatibility

Non-Magnetic and highly translucent to X-ray. CT/MRI imaging diagnosis without scattering or artifacts.

🎯 Perfect Contour Reconstruction

CAD/CAM technology allows for restoring defect models and reconstructing natural contours. Precisely matches the natural anatomy for convenient implantation.

🖼️ Product Display
Implant Display 1
Implant Display 2
Implant Display 3
Implant Display 4
Implant Display 5
❓ Frequently Asked Questions
What is a PEEK Patient Specific Implant (PSI)?
It is a custom-made implant designed using CAD/CAM technology to perfectly match the unique anatomical requirements of a patient's cranio-maxillofacial defect.
Is the PEEK material compatible with medical imaging?
Yes, PEEK is non-magnetic and highly translucent to X-rays, allowing for CT and MRI diagnostic imaging without artifacts or scattering.
What are the biocompatibility features of this implant?
The material is non-cytotoxic, non-carcinogenic, corrosion-resistant, and can withstand repeated steam, ETO, and Gamma irradiation sterilization.
How does the mechanical strength compare to natural bone?
The implant offers tensile strength exceeding native bone, providing superior protection to the cerebrum while effectively distracting stress during deformity.
What applications is this implant suitable for?
It is primarily used for craniomaxillofacial repair, reconstruction, deformity correction, and fracture fixation.
How is the perfect fit achieved for each patient?
We use advanced CAD/CAM technology to restore defect models and reconstruct the natural contour based on the patient's specific anatomy.

Related Products